About Fire-Concept

Fire is a hazardous disaster that can cause a lot of damage to property and human life. Fire extinguishers and other fire safety products ensure the minimisation of damage caused and prevent such disasters completely. Every year crores of property are gutted in fire incidents. According to a survey conducted, approximately 35 Indians lose their lives every day in fire accidents. We collectively can avert and reduce fire-related incidents. Our company's motto is to create awareness about fire safety and manufacture the best quality fire safety products.

Fire Concept is central India's first Bureau of Indian Standard (BIS) approved (IS 15683:2018) manufacturing unit based at MIDC industrial area, Butibori, Nagpur. The quality of manufactured products and services provided by Fire Concept is as per Indian standard. Fire Concept is CE as well as an ISO 9001: 2015 certified company.

Certifications

Our Mission

Our mission is to spread awareness regarding fire safety and to be a leading manufacturer of high-quality fire safety products and to save our consumers assets by providing them with best services.

Our Vission

Our vision is to, aware and prevent the world from the hazardous of fire related accidents and to save human life, environment, resources and assets.

Why FireConcept?

At Fire Concept, we make sure that each product manufactured and the services provided are as per the standards stated by the government. At Fire Concept, we have state of the art laboratory with latest testing equipments. The latest operational machinery helps us to provide top-notch quality products and services. Because of our quality and testing facilities our products have received high fire rating as compared to most of the companies in the market.

Every fire extinguisher at Fire Concept is manufactured with high-quality steel from world-class renowned companies like Tata and Jindal steel. The thickness of each cylinder is a minimum of 1.5 mm, which is 30% more than the required of 1.2 mm by IS. At the Fire Concept, every fire extinguisher passes through leakage test and hydraulic pressure test at 35 bar. Out of every batch, random samples are collected which undergo the following tests as per the BIS standard.

Resistance to temperature changes

Portable extinguishers shall operate at temperatures within one of the temperature range as given by IS. Fire extinguishers are kept either in an oven or deep freezer for 24 hours to check the performance. The extinguishers manufactured by us can operate in a higher range of -30ºC to +60°C, which is the highest range and very few companies can provide extinguishers in this range.

Burst test

This test enables the capacity of the cylinder to sustain pressure. As per standard test pressure, for low-pressure extinguishers should not be less than 35 bar, and burst pressure should not be less than 55 bar . The extinguishers manufactured at Fire Concept pass all these tests, and the cylinder bursts at not less than 90 bar on the body. It proves the quality of our fire extinguishers.

Cyclic pressure test

During this test our extinguisher sustains without rupture 5000 cycles from 0 to the test pressure i.e. Pt=35 bar and back to 0 bar at the same rate of 6 cycles/min.

Tapping test

During this test, charged extinguishers are dropped 500 times from a height of 15 mm.

Mechanical Resistance (Impact Resistance) test

This test intends to prove the resistance of the extinguisher, and particularly that of the head of the fittings from damage from falling objects or impact with fixed surfaces. The extinguisher shall be judged fit and proper if during the impact tests there is no evidence of bursting, breakage or ejection of components that risks the safety of the user.

Resistance to corrosion test (Salt Spray test)

During this test a completely charged fire extinguisher undergoes a salt spray test for 240 hours following a drying period of 24 hours at room temperature.

Crushing test

We crush the extinguisher and reduce it to 1/3 of its original outer diameter. Then we fill the extinguisher with water and increase the pressure to 35 bar. The extinguisher shall not exhibit any cracks or leaks.

Vibration test

An extinguisher must be capable of standing exposures to the conditions of vibration test without the development of physical weakness that impairs its operation.

Discharge test

This test is to check the minimum effective discharge time and bulk range of the discharge. It is also to verify the percentage of powder discharged.

Load bearing test

Brackets provided along with the fire extinguisher are tested five times with the weight of a complete charged cylinder. At Fire Concept, we believe in the quality and safety of end-users. Our team works hard and follows all timely guidance from BIS to provide the best quality products and services to you. Fire Concept is always there to assist you to save your life and assets.

Your first step to calm fire

Exclusive Services

serv-icon3-1.png

Refilling Services with Hydro Testing

We provide refilling services for all types of fire extinguisher, such as ABC dry powder type, CO2 type , water and foam type fire extinguishers

Read More
serv-icon3-2.png

AMC(Annual Maintenance Contract)

We provide an annual maintenance contract for the existing fire fighting equipment installed at the site.

Read More
Dry Run / Mock Drill / Training / Presentation

Dry Run / Mock Drill / Training / Presentation

In the event of a fire, the most critical factor is to know how to use the fire and safety products.

Read More
Accident brings tears, fire safety brings cheers.

Company Certifications

Don’t let your Dream go up in Smoke
Ensure fire Safety, Save Life, Save property with Fire-Concept ...
+91-7588550099, 9921951786

© 2021 / ALL RIGHTS RESERVED